Security sensors, especially wireless,  must be enrolled locally on an Interlogix Concord 4 keypad.

An alpha-numeric keypad is required for programming.

 
Key Function
# Select item (Enter)
* Go back one tier (Escape or exit)
A Scroll up within the menu
B Scroll down within the menu
C Insert pause when entering phone numbers
D Delete (where applicable)
1 Off (where applicable)
2 On (where applicable)

Programming

To enter programming mode on the keypad:
  1. Press [8] .
  2. Enter the installer code (default is 4321).
  3. Press [00] for the command. The screen displays System Programming .
  4. Press [#] to enter programming mode.
To exit programming mode on the keypad:
  1. Press [*] until the keypad displays System Programming .
  2. Press [A] and the screen displays Exit Programming . The Ready light blinks.
  3. Press [#] and the display returns to the time and date.

 

To enroll sensors using the keypad:

  • Press [8].
  • Enter the Installer Code.
  • Press [00] for the command. The screen displays System Programming.
  • Press [#] to enter programming mode.
  • Scroll to Sensors, then press [#] to select.
  • Scroll to Learn Sensors, then press [#] to select.
  • Enter the sensor partition number, then press [#]. This is generally “1” for partition one.
  • Enter the sensor group number, then press [#].
    • Instant Perimeter Zone = 13
    • Normal Exit/Entry Delay Zone = 10
    • Motion Detector Zone = 17
    • Smoke/Heat Zone = 26
    • Freeze Zone = 29
    • Carbon Monoxide Zone = 34
    • Flood Sensor Zone = 38
  • Manually tamper the sensor to be recognized by the panel. Take the cover off of the transmitter to cause a Tamper

To remove sensors using the keypad:

  1. Press [8] .
  2. Enter the installer code.
  3. Press [00] for the command. The screen displays System Programming .
  4. Press [#] to enter programming mode.
  5. Scroll to Sensors , then press [#] to select.
  6. Scroll to Delete Sensors , then press [#] to select.
  7. Scroll to the sensor to remove, then press [#] to remove the selected sensor. The screen displays Done when a sensor is successfully removed.
  8. Continue to remove any other sensors, or exit programming.